Mains PYQs
UPSC IFoS Mains Mech Engg paper 2 2020 questions
- What is the reversible adiabatic work for a steady flow system when KE and PE changes are negligible? How is it different from a closed stationary system?
- Explain various methods to increase the power output of the IC engines with same volumetric capacity.
- The inner and outer surfaces of a spherical container are maintained at temperatures of $T_1 = 200\,^\circ\mathrm{C}$ and $T_2 = 80\,^\circ\mathrm{C}$, respectively. The container is having the following dimensions:
Inner radius = 8 cm, outer radius = 10 cm
The thermal conductivity of the container material is 45 W/m-K. Obtain a general relation for the temperature distribution inside the container under steady conditions and also, determine the rate of heat loss from the container.
- A Carnot refrigerator has working temperatures of $-30\,^\circ\mathrm{C}$ and $35\,^\circ\mathrm{C}$. If it operates with R12 as a working substance, calculate the work of isentropic compression and that of isentropic expansion. Also, calculate the refrigerating effect, heat rejected per kg of the refrigerant and COP of the cycle.
- Explain the phenomena of surge and choking in centrifugal compressors.
- Air at $10\,^\circ\mathrm{C}$ and 80 kPa enters the diffuser of a jet engine steadily with a velocity of 200 m/s. The inlet area of the diffuser is $0.4\,\mathrm{m^2}$. The air leaves the diffuser with a velocity that is very small compared with the inlet velocity. Determine
(i) the mass flow rate of the air;
(ii) the temperature of the air leaving the diffuser.
- Why is the slope of the sublimation curve at the triple point on the $p$-$T$ diagram greater than that of the vaporization curve at the same point?
- The fuel consumption of an SI engine is 0.5 kg of fuel per minute. The air-fuel ratio is 10. The air is supplied at 1 bar and $27\,^\circ\mathrm{C}$. The specific gravity of the fuel is 0.75. If the flow velocity of the choke is 100 m/s, velocity coefficient is 0.8 and the pressure drop across the fuel metering orifice is 0.80 to that of the choke, calculate the diameter of the orifice. Assume the orifice coefficient of discharge as 0.6.
- An 80 kW CI engine consumes 0.3 kg of fuel per minute consisting of 14% hydrogen and rest carbon. The calorific value of the fuel is 45.1 MJ/kg. The engine jacket cooling water is also passed through the exhaust calorimeter before discharge with the following observations. (i) Calculate the actual amount of the air supplied, (ii) find the mass of the exhaust gases discharged and (iii) draw the heat balance table of the engine:
(1) Amount of the water supplied per hr = 1000 kg
(2) Temperature of the water entering the engine jacket = $20\,^\circ\mathrm{C}$
(3) Temperature of the water leaving the engine jacket = $60\,^\circ\mathrm{C}$
(4) Temperature of the water leaving the exhaust calorimeter = $90\,^\circ\mathrm{C}$
(5) Temperature of the exhaust gases leaving the calorimeter = $150\,^\circ\mathrm{C}$
(6) Temperature of the exhaust gases leaving the engine = $400\,^\circ\mathrm{C}$
Assume the specific heat of the exhaust gases as 1.05 kJ/kg-K. Assume testing at full load.
- What are the problems associated with cold weather operation of CI engines? Also, write in brief about their remedial measures.
- Calculate the decrease in available energy when 30 kg of water at $98\,^\circ\mathrm{C}$ is mixed with 40 kg of water at $38\,^\circ\mathrm{C}$, the pressure being taken as constant and the temperature of the surroundings being $18\,^\circ\mathrm{C}$. ($C_p$ of water = 4.2 kJ/kg-K)
- From a performance test on a well-baffled single-shell, two-tube-pass heat exchanger, the following data are available:
Oil ($C_p$ = 2100 J/kg-K) in turbulent flow inside the tubes entered at 340 K at the rate of 1 kg/s and left at 310 K; water flowing on the shell side entered at 290 K and left at 300 K
A change in service conditions requires the cooling of a similar oil from an initial temperature of 370 K but at three-fourths of the flow rate used in the performance test. Estimate the outlet temperature of the oil for the same water flow rate and inlet temperature as before.
[Figure] Chart: correction factor $F$ to counterflow LMTD for heat exchanger with one shell pass and two tube passes ($F$ against $P = (T_{t,out} - T_{t,in})/(T_{s,in} - T_{t,in})$); chart: heat exchanger effectiveness for shell and tube heat exchanger with one well-baffled shell pass and two tube passes (effectiveness against NTU = $AU/C_{min}$ for $C_{min}/C_{max}$ = 0, 0.25, 0.50, 0.75, 1.00).
- A large body of non-luminous gas at a temperature of $1100\,^\circ\mathrm{C}$ has emission bands between 2.5 µm and 3.5 µm and between 5 µm and 8 µm. At $1100\,^\circ\mathrm{C}$, the effective emissivity in the first band is 0.8 and in the second band is 0.6. Determine the emissive power of this gas in $\mathrm{W/m^2}$.
- A nuclear reactor fuel rod is a circular cylinder of 6 cm diameter. The rod is to be tested by cooling it with a flow of sodium at $205\,^\circ\mathrm{C}$ with a velocity of 5 cm/s perpendicular to its axis. If the rod surface is not to exceed $300\,^\circ\mathrm{C}$, estimate the maximum allowable power dissipation in the rod.
- A 1 kW electric heating element is immersed in 25 kg of water initially at $12\,^\circ\mathrm{C}$ in an insulated container. Determine the time required for the heater to raise the water temperature to $65\,^\circ\mathrm{C}$. Also, find the entropy generated during this process.
- It is a well-known fact that the two-stroke engines are more polluting than four-stroke engines. However, they are extensively used in some applications. Give the reasons and list these applications.
- A long steam pipe having 10 cm diameter and whose external surface temperature is $110\,^\circ\mathrm{C}$, passes through an open area that is not protected against winds. Determine the rate of heat loss from the pipe per unit of its length when the air is at 1 atmosphere pressure and $10\,^\circ\mathrm{C}$. The wind is blowing across the pipe at a velocity of 8 m/s. Also, determine the rate of heat loss from the pipe if the length of the pipe is 25 m.
- Derive an expression for the COP of an ideal vapour absorption system in terms of temperatures at important points of the system. Also, comment on the relevance of COP of vapour absorption system with that of the COPs of Carnot refrigerator and Carnot engine.
- When is a natural draught cooling tower a good choice? What is the minimum temperature to which water can be cooled? Explain the functioning of induced draught counterflow cooling tower.
- The inside and outside conditions in an air-conditioning system are as:
Inside dry-bulb temperature - $25\,^\circ\mathrm{C}$
Outside dry-bulb temperature - $40\,^\circ\mathrm{C}$
Inside relative humidity - 50%
Outside wet-bulb temperature - $27\,^\circ\mathrm{C}$
The room sensible heat factor - 0.8
Fifty percent of the room air is rejected to atmosphere and an equal quantity of fresh air is added before air enters the system. If the fresh air added is $100\,\mathrm{m^3}$/minute, then find the following:
(i) Room sensible and latent load
(ii) Sensible and latent heat load due to fresh air
(iii) Apparatus dew point
(iv) Humidity ratio and dry-bulb temperature of air entering the system
Assume by-pass factor as zero, density of air as $1.2\,\mathrm{kg/m^3}$ at a total pressure of 1.01325 bar.
[Figure] Psychrometric chart (barometric pressure 1.01325 bar, sea level).
- An air-conditioning system has to be designed for a conference hall. The design conditions are as:
Inside conditions - $25\,^\circ\mathrm{C}$ DBT, 50% RH
Outside conditions - $40\,^\circ\mathrm{C}$ DBT, $28\,^\circ\mathrm{C}$ WBT
Occupants - 25 persons
Sensible heat gain per person - 58 W
Latent heat gain per person - 58 W
Solar heat gain through glass windows - 5.52 kW
Solar heat gain through roof and walls - 5.87 kW
Lighting load - 15 lamps of 100 W each and 10 fluorescent lights of 80 W each
Sensible heat gain from other sources - 11.63 kW
Infiltrated air - $15\,\mathrm{m^3}$/minute
If 75% recirculated air and 25% fresh air are mixed and passed through the air conditioner coil, then find the following:
(i) Amount of total air required
(ii) Dew point temperature of the coil
(iii) Condition of supply air to the room
(iv) Capacity of the conditioning plant
Assume by-pass factor as 0.2.
[Figure] Psychrometric chart (barometric pressure 1.01325 bar, sea level).
- A mixture of room air and fresh air enters a cooling coil at the rate of $39.6\,\mathrm{m^3}$/minute. The dry-bulb and wet-bulb temperatures of the mixture are $31\,^\circ\mathrm{C}$ and $18.5\,^\circ\mathrm{C}$, respectively. The surface area of the coil is such as would give 12.5 kW of refrigeration with the given entering air conditions. The effective surface temperature of the coil is $4.4\,^\circ\mathrm{C}$. Determine the exit conditions of the air and the by-pass factor.
[Figure] Psychrometric chart (barometric pressure 1.01325 bar, sea level).
- Air at ambient conditions of 1.01 bar and 288 K enters an axial flow compressor which has an overall pressure ratio of 4.0 and mass flow rate of 3.5 kg/s. If the polytropic efficiency is 90% and the stagnation temperature rise per stage is 28 K, calculate the number of stages required and the pressure ratio of the first and last stages. Assume equal temperature rise in all stages. If the absolute velocity approaching the last rotor is 170 m/s at an angle of $20^\circ$ from the axial direction, the work done factor is 0.85, the velocity diagram is symmetrical and the mean diameter of the last stage rotor is 20 cm, calculate the rotational speed and the length of the last stage rotor blade at inlet to the stage.
- What is pressure coefficient for a centrifugal compressor stage? Derive $\psi = 1 - \phi_2\cot\beta_2$ and plot $\psi$-$\phi_2$ curves for radial, forward and backward swept impeller blades.
- Compare a 2-stage reaction turbine, a 2-stage impulse turbine and a Curtis wheel with 2 rows of rotating blades, and bring out merits and demerits of them.
- Show the following acting on a turbine blade cascade:
(i) Inlet, mean and outlet velocity triangles
(ii) Lift, drag, axial and tangential forces
Prove that
(iii) $C_L = 2\left(\frac{s}{l}\right)\cos\alpha_m(\tan\alpha_1 + \tan\alpha_2) + \left(\frac{s}{l}\right)Y\frac{\cos^2\alpha_m}{\cos^2\alpha_2}\sin\alpha_m$
(iv) $C_D = Y\left(\frac{s}{l}\right)\frac{\cos^3\alpha_m}{\cos^2\alpha_2}$
where $Y$ = pressure loss coefficient.
- Explain the principle of fluidized bed combustion and working of a circulating fluidized bed boiler. List the advantages of such boilers over other solid fuel-fired boilers.
- A forced draught fan supplies air at 12 m/s against a draught of 25 mm of water across the fuel bed. Estimate the power required to run the fan if 3000 kg/hr of coal is consumed and 16 kg of air is supplied per kg of coal burned. The temperature of the flue gas and the ambient air may be taken as 650 K and 300 K, respectively.
If the forced draught fan is replaced by an induced draught fan, what will be the power required to drive the fan?